Versio IOX Scale-Out NAS SINGLE is an economical, entry-level storage solution designed for smaller applications that do not require high availability. It is ideal for customers who have a SAN, but need to move to a NAS to accommodate editing applications, or for customers who eventually want the higher performance of a Scale-Out NAS — but with a lower initial investment.
Delivering cost-effective, sharable and scalable storage throughout the content lifecycle, Versio IOX Scale-Out NAS SINGLE allows customers to enjoy the benefits of NAS, such as the simplicity of a single entry point and the lower scaling cost of Ethernet rather than expensive Fibre Channel.
A Versio IOX Scale-Out NAS SINGLE filesystem has a single controller active/active pair that manages the entire namespace. Its single-stack simplicity allows for easy configuration and does not require additional elements to manage. However, controllers and disks can be added to the system as separate volumes or shares, with the addition of an asset-management layer to move and duplicate media between volumes.
Versio IOX Scale-Out NAS SINGLE delivers numerous real-world benefits:
Specifications and designs are subject to change without notice
General Information | |
---|---|
Core Chasis | Active/Active controller module pair per enclosure 2x SAS I/O ports per module connecting to the controller node 1 x 4-lane 6Gb mini-SAS connector per module |
Store Chasis | Dual SAS Connector modules with two 4-lane 6Gb mini-SAS connectors per module |
Management/Status Reporting (some optional components and plugins require additional license) | HPE Storage Management Utility (SMU). Management access, out-of-band: WEB GUI, CLI. Interface Types: USB 100/1000 Ethernet. Protocols Supported SNMP, SMI-S, SSL, SSH, SMTP, FTP, HTTP, Telnet HPE OneView for VMware vCenter vStorage API for Array Integration in vSphere VMware Site Recovery Manager(SRM) Plugin HPE StoreFront Manager for Microsoft Hyper-V HPE MSA Remote Snap software |
Maximum Stack Configuration | 3.5" Controller & Expansion — 8 enclosures, total 96 drives 2.5" Controller & Expansion — 8 enclosures — total 199 drives |
Maximum Single Volume Configuration | Maximum 64 LUNs (128 LUNs mirrored) IOX Storage Pools — 1 stack of up to 8 enclosures NAS — up to 8 pools, total 64 enclosures |
Protection Levels | RAID-6 |
Hot-Swappable Components | Disk drives, PSU/cooling modules, Core RAID Controllers, Expansion SAS modules, and all cabling |
Physical | Height: 8.9 cm (3.5") 2 EIA Units Width: 44.7 cm (17.6") IEC Rack Compliant Depth: 24-bay 2.5" Controller array: 19.5 in / 49.5 cm Depth: 25-bay 2.5" Expansion array: 22.3 in / 56.7 cm Depth: 12-bay 3.5" Controller/Expansion: 22.5in. / 57.2 cm Weight (no controllers): 12-bay 3.5" Controller/Expansion: 31 lbs. (DC-pwr model: 32.6 lbs) Weight (no controllers): 24-bay 2.5" Controller array: 29.1 lbs (DC-pwr model: 30.7lbs) Weight (no controllers)t: 25-bay 2.5" Expansion array: 38 lbs |
Disk Drives | |
---|---|
Drive Types and Sizes | High drive density with the following available options: 3.5" 10TB SAS 7.2K Hard Drive 3.5" 8TB SAS 7.2K Hard Drive 3.5" 6TB SAS 7.2K Hard Drive 3.5" 4TB SAS 7.2K Hard Drive 3.5" 2TB SAS 7.2K Hard Drive 3.5" 4TB SAS 7.2K Self Encrypted Hard Drive 3.5" 2TB SAS 7.2K Self Encrypted Hard Drive 2.5" 2TB SAS 7.2K Hard Drive 2.5" 1TB SAS 7.2K Hard Drive 2.5" 1.8TB SAS 10K Hard Drive 2.5" 600GB SAS 15K Hard Drive 2.5" 1.2TB SAS 10K Self Encrypted Hard Drive 2.5" 3.2TB SAS Solid State Drive (SSD) 2.5" 1.6TB SAS Solid State Drive (SSD) 2.5" 800GB SAS Solid State Drive (SSD) 2.5" 400GB SAS Solid State Drive (SSD) 2.5" 200GB SAS Solid State Drive (SSD) |
Cache | 6GB per controller |
Read/Write Cache | 4GB per controller |
Mean Time Between Failures (MTBF) | 1.2 million hours or higher |
Annual Failure Rate (AFR) at full 24/7 operation | 0.73% (at full 24x7 operation) |
Transfer Rate, Sustained | 147 Mb/s or higher |
Power Consumption (idle) | 9.0 W or lower |
Environmental | |
---|---|
Input Power Requirements | 110VAC 3.32A, 344-390 W; 220VAC 1.61A, 374-432W |
Maximum Input Power | 100-240 VAC, 50/60 Hz., 4.5-1.9A; 48-60 VDC 10.4A/8.3A |
Power Supply Efficiency | Bronze Rated - high efficiency 82% @ 20% load 86% @ 80% load 85% @ 100% load |
Heat Dissipation | 1622 BTUs/hour |
Operational Temperature | 41º to 104º F (5º to 40º C)Note: Derate 2 C for every km, up to 3000 meters |
Non-Operational Temperature | -40º to 158º F (-40º to 70º C) |
Operational Humidity | 10% to 90% RH @ 104º F (40º C), non-condensing |
Non-Operational Humidity | Up to 93% RH @ 104º F (40º C), non-condensing |
Operational Shock | 3G's for 11 ms |
Non-Operational Shock | 15G's 11 ms, ½ sine |
Operational Vibration | 5 to 500 Hz, 0.14 g shaped |
Non-Operational Vibration | 3-365-3Hz, 1.22 g, z-axis, 0.85 g, X&Y axis shaped spectrum |
Declared Acoustics Noise Levels | Sound Power: LWAd=6,75 B Sound Pressure: LpAm — 55 dBA |
REGULATORY / CERTIFICATION | |
---|---|
Compliance | NEBS Level 3 |
Safety | UL 60950-1, 1st edition (United States) CAN/CSA-C22.2 No.60950-1-03 (Canada) EN 60950-1 (European Union) IEC 60950-1 (International) EN 60950-1 (GS Mark,Germany) CCC Mark China (PRC) |
Electromagnetic Compatibility Emissions | VCCI:2008-04 Class A (Japan) EN 55022 Class A (EU); CISPR 22 (International Class A) AS/NZS CISPR 22 Class A (Australia, New Zealand) VCCI Class A (Japan) KN 22 Class A (S. Korea) FCC 15:109(g) Class A (USA) ICES-003:2004 Class A (Canada) |
Harmonics / Flicker Immunity | EN61000-3-2 (EU) EN 61000-3-3 (EU) EN 55024 (EU) KN 24 (S. Korea) |
RoHS and WEEE | RoHS-6/6 Compliance, China RoHS, WEEE |
Country Approvals | United States, Australia/New Zealand, Canada, China (PRC), European Union (EU), Germany, Japan, South Korea, Taiwan |
Manufacturer | Imagine Communications |
---|