The Nexio MOS Gateway is a key component of the Imagine Communications NewsForce HD/SD news platform, providing interoperability between MOS-compliant newsroom computer systems and NewsForce applications.
The Nexio MOS Gateway is suitable for newsroom systems of all sizes. It connects your newsroom computer system (NRCS) through the NRCS local area network (LAN) to the Nexio server system LAN. It provides communication between your NRCS and Nexio news applications using standard MOS protocol.
Supported Applications:
The Nexio MOS Gateway monitors changes in rundowns and scripts of the NRCS. It communicates these changes to all Nexio MOS applications, including Nexio MOS Playlist Manager and Nexio MediaBase ActiveX plug-in (NXMB), as well as to the newsroom system tools in Velocity ESX, Velocity XNG, Velocity PRX, and Apple Final Cut Pro.
Status of content associated with MOS active rundowns is fed back to the newsroom system users. As status of media changes, users receive immediate notifications, including during playout.
Using the Nexio MOS Gateway, Nexio NewsForce interacts in real time with ENPS, Avid iNEWS, OCTOPUS, Autocue QNews and Annova OpenMedia newsroom systems.
NewsForce users have direct access to MOS active rundowns and scripts. Users are able to create placeholders in scripts from inside the newsroom system, forming a link to the playout system for content that will be created later in the production process by Nexio ingest or editing systems.
Specifications and designs are subject to change without notice
System Configuration | |
---|---|
Server Hardware Features | 1RU Rack Mount 1+1 redundant hot-swappable power supply, 800W (100-240VAC) or 1400W (200-240VAC) High CFM cooling for 24/7 operation 2 Intel Xeon 64-bit Haswell 6-core processors 32 GB DDR4 RAM expandable to 1536 GB 1+1 redundant front-mounted hot-swappable OS SSDs 4x 1GbE Ethernet Ports Optional additional 4x 1GbE, or 2x 10GbE, or 2x 40GbE Ethernet Ports 1x VGA monitor port 3 USB 3.0 ports (1 front, 2 rear) Dedicated Hewlett Packard Enterprise Integrated Lights-Out (iLO) Ethernet Port Windows Server 2012 R2 Standard 64-bit Embedded OS |
Server Physical Attributes | |
---|---|
Dimensions | 8 SFF and 10 SFF 1.7 x 17.1 x 27.5 inches (4.32 x 43.47 x 69.85 cm) |
Weight (approximate) | Minimum (one hard drive, power supply, and processor installed): 8SFF Model 27lb. (12.25 kg) |
Maximum (all hard drives, power supply, and processor installed): 8 SFF Model 33.3 lb. (15.31 kg) Note: Includes 2 SFF Option for a total of 10 SFF HDD |
Power & Cooling | |||
---|---|---|---|
BTU Rating | For 800W Power Supply: 3207 BTU/hr (at 100 VAC), 3071 BTU/hr (at 200 VAC), 3112 BTU/hr (at 240 VAC) for China Only | ||
Power Supply Output | Rated Steady-State Power: | For 1400W Power Supply: 1400W (at 240 VAC), 1400W (at 240 VAC For 800W Power Supply: 800W (at 100 VAC), 800W (at 240 VAC), 800W (at 240 VAC) input for China only |
|
Maximum Peak Power: | For 1400W Power Supply: 1400W (at 200 to 240 1VAC), 1400W (at 240 VAC) input for China only For 800W Power Supply: 800W (at 100 to 127 VAC), 800W (at 200 to 240 1VAC), 800W (at 240 VAC) input for China only |
Emissions Classification (EMC) | FCC Rating | Class A |
Normative Standards | CISPR 22; EN55022; EN55024; FCC CFR 47, Pt 15; ICES-003; CNS13438; GB9254; K22;K24; EN 61000-3-2; EN 61000-3-3; EN 60950-1; IEC 60950-1 |
System Inlet Temperature | Standard Operating Support: | 10 to 35C (50 to 95F) at sea level with an altitude derating of 1.0C per every 305 m (1.8F per every 1000ft) above sea level to a maximum of 3050 m (10,000ft), no direct sustained sunlight. Maximum rate of change is 20C/hr (36F/hr). The upper limit and rate of change may be limited by the type and number of options installed. Note: System performance during standard operating support may be reduced if operating with a fan fault or above 30C (86F). |
Relative Humidity | Operating: | Minimum to be the higher (more moisture) of -12C (10.4F) dew point or 8% relative humidity. Maximum to be the lower (less moisture) of 24C (75.2F) dew point or 90% relative humidity. |
Non-operating: | 5 to 95% relative humidity (Rh), 38.7C (101.7F) maximum wet bulb temperature, non-condensing. |
Altitude | Operating: | 3050 m (10,000 ft). This value may be limited by the type and number of options installed. Maximum allowable altitude change rate is 457 m/min (1500 ft/min). |
Non-operating: | 9144 m (30,000ft). Maximum allowable altitude change rate is 457 m/min (1500ft/min). |
Acoustic Noise | ||
---|---|---|
Listed are the declared A-Weighted sound power levels (LWAd) and declared average bystander position A-Weighted sound pressure levels (LpAm) when the product is operating in a 23C ambient environment. Noise emissions were measured in accordance with ISO 7779 (ECMA 74) and declared in accordance with ISO 9296 (ECMA 109). | ||
Idle | Operating | |
L WAd | (1P non-redundant) 4.6 A Average Bystander (2P redundant) 5.5 A Average Bystander |
(1P non-redundant) 4.6 A Average Bystander (2P redundant) 6.2 C Average Bystander |
L pAm | (1P non-redundant) 29 dBA (2P redundant) 37 dBA |
(1P non-redundant) 30 dBA (2P redundant) 46 dBA |
Note: 1P Configuration tested included two Intel E5-2630 v3, 2.3GHz processors, one 500GB SAS HDD, five standard hot plug fans, one 8GB DDR4 RDIMM's 2133MHz, one 500W power supply. 2P Configuration tested included two Intel E5-2650 v3, 2.6GHz processors, one 500GB SAS HDD, seven standard hot plug fans, two 16GB DDR4 RDIMM's 2133MHz, one 500W power supply, P440ar HDD controller PCI card with 2GB cache. Performance of system, options, and ancillary equipment will vary depending on the system configuration. |
Manufacturer | Imagine Communications |
---|