For-A IP Changeover Switcher (2 inputs) - IPS-6200

Standalone ASI/TS over IP changeover in a 1U enclosure. Monitors TS-level IP signals in redundant input and instantly switches ports if errors occur, enabling seamless output without disruptions
Manufacturer: For-A
$8,360.00
Availability: In stock
SKU
IPS-6200
Manufacturer: For-A

For-A IP Changeover Switcher (2 inputs) - IPS-6200

Clean Switching Over IP

Increasing IP circuit reliability

Standalone ASI/TS over IP changeover in a 1U enclosure. Monitors TS-level IP signals in redundant input and instantly switches ports if errors occur, enabling seamless output without disruptions.

IP-based changeover for monitoring redundant TSoIP signals from multicast TS-level encoder transmissions and seamlessly switching ports if errors occur. To prevent transmission path error, this changeover further increases the reliability of duplex transmission.

Seamless switching between outputs of the same encoder

When installed at the far end of a network link, the IPS-6200 seamlessly switches between redundant encoder TSoIP input used in multicast transmissions or the like. This supports completely seamless switching without video or audio disruption.

Auto and manual switching 

When a signal error occurs, the IPS-6200 automatically switches to the other line. Manual switching and auto/manual assignment of each line are also possible. For example, the following assignment can be selected: Automatic switching from the current line to the reserve line, and manual switching from the reserve line to the current line.

Delay adjustment function

 The delay difference between different lines is absorbed quickly and both phase inputs are automatically aligned to achieve seamless switching that does not disrupt the output. The delay adjustment range is up to 10 seconds.

TS-level monitoring

TS-level error monitoring, already proven reliable in switching, is used for IP signals. Error monitoring goes beyond TR 101 290 guidelines to check for packet loss, null-only, and other critical errors affecting signal quality. Error detection can also be enabled or disabled based on the type of signal. Set the PID error detection threshold as desired, in 1 ms increments. Up to four sets of multi-program signals are supported.

GUI-based remote control and monitoring 

Ethernet interfaces enable a wide range of remote monitoring and control to suit many usage scenarios. The dedicated GUI can be used to make settings and graphically display error monitoring contents via Ethernet. An event log viewer, automatic CSV file generation, and other functions are also provided to facilitate signal management requiring historical condition data. SNMP-based control, configuration, and monitoring is also supported.

ASI and IP input both supported

Choose ASI or IP for each signal supplied. Enables mixed input, using IN 1 on the IP side and IN 2 on the ASI side, for example. Ideal for redundant ASI/satellite operation.

Specifications

IP port

Transmission standard

IEEE 802.3ab / IEEE 802.3u compliant

Connector

RJ-45 (Input × 2, Output × 1)

ASI port

Signal standard

DVB-ASI (EN50083-9) compliant

Input

Packet / Burst, 188 / 204 bytes

Output

Packet, INPUT / 188 byte fixed /204 byte fixed

Effective bit rate

1 Mbps to 200 Mbps

Connector

75Ω unbalanced BNC (Input × 2, Output × 2)

Pass-through

Pass-through from IN 1 to OUT (via mechanical relay) when the power is turned off

TS over IP

Transmission standard

SMPTE 2022-2

Transmission protocol

RTP/UDP/IPv4

FEC

SMPTE 2022-1 / Pro-MPEG CoP#3

Communication format

Unicast/multicast (IGMPv2)

TSP over IP

1-7

Monitor/control system

Buffer capacity for delay adjustment

10 seconds

System delay

Standard 50 ms / min. 5 ms (depends on the offset value)

Error detection item
(Can be enabled/disabled for each signal)

·                                 No signal

·                                 Packet loss (including illegal code error)

·                                 TR101 290 P1 / P2 (PMT 1-4 error detection for MPTS can be configured individually.)

·                                 NULL only error

CC / PID error details
(Can be enabled/disabled for each signal)

Automatically detected PID:
  PAT / PMT / VIDEO / AUDIO1 / AUDIO2 / AAC AUDIO1 / AAC AUDIO2 / DATA1 / DATA2
USER_PID:
  USER1_PID / USER2_PID / USER3_PID

External control

ETHERNET

10BASE-T / 100BASE-TX / 1000BASE-T

·                                 Signal status monitoring / Main unit setting / Log viewer / File save function by dedicated GUI

·                                 SNMP monitoring / control by means of dedicated MIB files (SNMP v1 / v2c) (Main unit control and notification of error traps for up to four different IP addresses)

·                                 For Maintenance (For firmware updates)

Other

Power

100 V AC to 240 V AC (hot-swappable redundant power supply)

Power consumption

30 W

Dimensions

430 (W) × 450 (D) × 44 (H) mm

Weight

Approx. 7 kg

Temperature / Humidity

5℃ to 40℃ / 85% or less (no condensation)

Note: Specifications subject to change without notice. Information valid as of January 2015.

 